CK和CK MB试剂对镁测定的影响
干扰;全自动分析;镁,,],干扰;全自动分析;镁,CK和CKMB试剂对镁测定的影响,1材料和方法,2结果,3讨论,参考文献:
[摘 要] 目的:研究全自动分析CK和CKMB试剂对镁测定的影响。方法:通过混合血清或蒸馏水标本单独测镁与先测CK或CKMB,再测镁的结果比较来讨论。结果:单独测镁与先测CK或CKMB,再测镁的结果存在差异显著性性。结论:CK和CKMB试剂因含高浓度镁,对镁测定有正干扰。[关键词] 干扰;全自动分析;镁
Influence on Detecting Magnesium by the Reagent of CK and CKMB
XU Junrong,LI Jing,SHI Ruihua
(The First Affiliated Hospital of Nanjing Medical University,Nanjing, Jiangsu 210029,China)
Abstract:Objective To study the effect of CK and CKMB reagent on detecting magnesium by an automatical analyzer.Methods Determination of magnesium was carried out alone,compared with it was done after measuring CK or CKMB.Results Significant differences were observed between the mean values of magnesium concentration in two groups.Conclusion CK and CKMB had significant influence on detecting magnesium,because they contented the high concentration of magnesium.
Key words:Interference;Automatical analysis;Magnesium
当生化检测处于手工或半自动分析时 ......