某三甲医院消毒灭菌连续三年主动监测效果分析(1)
http://www.100md.com 2019年3月12日 《医学信息》 2019年第10期
     摘要:目的 分析我院连续三年消毒灭菌的环境卫生学监测结果,查找薄弱环节,确保消毒灭菌质量,预防控制医院内感染的发生。方法 回顾性分析我院2016~2018年消毒灭菌及环境卫生学监测资料,分析检测样本合格率及比合格标准分布情况。结果三年共监测物体表面、空气、手指表面、内镜、透析液及透析用水等标本3458份,监测合格标本3419份,合格率为98.87%。不合格标本分别为:医务人员手19份,物体表面10份,内镜8 份,消毒液2份。三年合格率分别为98.93%,98.75% 和98.93%,差异无统计学意义(P>0.05)。结论 我院消毒灭菌质量总体情况良好,通过监测,反馈,培训,整改,再监测的良性循环,有效的预防控制了院内感染的发生。

    关键词:消毒灭菌;主动监测;卫生监测;院内感染

    中图分类号:R187 文献标识码:A DOI:10.3969/j.issn.1006-1959.2019.10.042
, 百拇医药
    文章编号:1006-1959(2019)10-0126-03

    Abstract:Objective To analyze the environmental hygiene monitoring results of disinfection and sterilization in our hospital for three consecutive years, to find weak links, to ensure the quality of disinfection and sterilization, and to prevent and control the occurrence of infections in hospitals. Methods The data of disinfection and environmental hygiene monitoring in our hospital from 2016 to 2018 were retrospectively analyzed, and the qualified rate of test samples and the distribution of qualified standards were analyzed.Results In the past three years, 3,458 specimens of surface, air, finger surface, endoscope, dialysate and dialysis water were monitored, and 3,419 qualified specimens were monitored, and the pass rate was 98.87%. The unqualified specimens were: 19 medical personnel, 10 surfaces, 8 internal lenses, and 2 disinfectants. The three-year pass rate was 98.93%,98.75% and 98.93%,respectively,the difference was not statistically significant(P>0.05).Conclusion The quality of disinfection and sterilization in our hospital is generally good. Through the virtuous cycle of monitoring, feedback, training, rectification and re-monitoring, effective prevention and control of nosocomial infections.
, 百拇医药
    Key words:Sterilization;Active monitoring;Health monitoring;Nosocomial infection

    根据卫生部《医院感染管理规范》(卫医发[2000]431號)[1]的要求,医院应进行环境卫生学监测,其目的是希望能及时发现医院环境中会造成医院感染的隐患,减少院内感染的发生。医院感染的预防与控制是保证医疗质量与医疗安全的重要内容,而医院环境对医院感染的发生有着重要影响,如果医院对环境卫生学监测不够重视会导致医院感染及暴发的发生[2]。研究证实,加强对医院环境卫生学进行监测,可显著减少医院感染的发生,对提升医疗服务质量具有十分积极的意义[3]。现将我院2016年1月~2018年12月连续三年重点部门监测效果分析如下。

    1资料与方法

    1.1资料来源 调取江苏省常州市第一人民医院2016年1月~2018年12月医院感染管理重点部门环境卫生学监测记录,监测科室包括:各个病区ICU、产房、新生儿科等病房,3个中心(消毒供应中心、静配中心、血液透析中心),内镜室(消化内镜室、支气管镜室),其他重点部门手术室、口腔科、血库、导管室等相关科室。, 百拇医药(李雪梅 狄佳 冯诚怿)